 Interlock Switches
Non contact Switches
Ferrogard 6, 9 & 10 Specifications
Standards EN954-1, ISO13849-1, IEC/EN60204-1, NFPA79, EN1088, ISO14119, ANSI B11.19, AS4024.1 Cat. 1 Device per EN954-1 Dual channel interlocks suitable for Cat. 3 or 4 systems CE marked for all applicable directives and cULus 1 N.C. Safety Contact 1 x 106 at rated load
Category
Approvals Contact Arrangements Electrical Life
Description
The Ferrogard range of magnetically actuated safety switches offers Non contact reliability together with tolerance to misalignment. They are designed to be installed so that when a guard door is opened, the action of the magnetic actuator being removed from the switch opens the N.C. safety contact which is intended for the isolation of control power to a machine primary control element. The FRS 6, 9 and 10 sensors and actuators incorporate slim housings to accommodate narrow mounting areas. They are environmentally sealed to IP67 (NEMA6P), which makes them ideal for wet environments. These Ferrogard switches have two active sensing faces allowing more flexible mounting options. Unlike some magnetic switches the Ferrogards have protected safety contacts to help ensure that they do not fail to danger. All Ferrogards have internal non-resettable overload protection on the safety contact. They should be protected by an external fuse rated as shown in the specifications table.
Safety Contact Switching Capability FRS 6 250V AC 2A max FRS 9 24V DC 1A max FRS 10 110V AC 3A max Safety Contact External Fusing FRS 6 <1.6A quick blow FRS 9 <0.8A quick blow FRS 10 <2.5A quick blow Operating Distance - Make Operating Distance - Break Closing Time Dropout Time Bounce Time Initial Contact Resistance Initial Capacitance, Terminal to Terminal Initial Insulation Resistance, Terminal to Terminal Min Initial Breakdown Voltage Mechanical Life Mounting Weight (not including cable) FRS 6 FRS 9 FRS 10 Case Material Cable Operating Temperature Environmental Vibration Shock 12mm (0.47in) 23mm (0.91in) 3.0ms 2.1ms 0.7ms 15m 0.65pF 1 x 106 600VAC 10 x 106 Any Position M4 mounting security screws included. Sensor Actuator 28g (0.06lbs) 70g (0.15lbs) 28g (0.06lbs) 70g (0.15lbs) 28g (0.06lbs) 70g (0.15lbs) Red moulded ABS Plastic 0.75mm2 (18 AWG) 2 wire Jacket OD 5.6mm (0.22in) -10C to +65C (14 to +149F) IP67 (NEMA 6P) 7-15g, 10 to 200Hz 50g
Features
* * * * * * Non contact actuation High tolerance to misalignment High switching current (up to 3A) Two sensing faces IP67 (NEMA 6P) Rating Slim housings
3-48
Interlock Switches
Non contact Switches
Ferrogard 6, 9 & 10 Product Selection
Safety Contact Switching Capability Housing Connection Material 2m Cable 4m Cable 6m Cable 10m Cable 4 Pin Micro QD 2m Cable 1 N.C. None ABS Plastic 4m Cable 6m Cable 10m Cable 4 Pin Micro QD 2m Cable 4m Cable Mating cable, 4-pin straight 2m. See page 15-10 for details and additional lengths. Mating cable, 4-pin straight 5m. See page 15-10 for details and additional lengths. Mating cable, 4-pin straight 10m. See page 15-10 for details and additional lengths.
Note: Contacts are described with the guard door closed, that is, actuator in place.
Safety Contacts
Auxiliary Contacts
Type
250V AC 2A
FRS 6
24V DC 1A
FRS 9
110V AC 3A
FRS 10
Catalogue Number 440N-G02023 440N-G02028 440N-G02032 440N-G02013 440N-G02095 440N-G02044 440N-G02075 440N-G02082 440N-G02089 440N-G02096 440N-G02045 440N-G02088 889D-F4AC-2 889D-F4AC-5 889D-F4AC-10
Accessories
Description Replacement Actuator Page Number -- Catalogue Number 440N-A02025
Approximate Dimensions--mm (inches)
Dimensions are not intended to be used for installation purposes.
Switch, Cable Version Actuator 19.5 (0.77) 4.5 (0.18) 73 (2.87) 7 (0.28) 19.5 (0.77) 13 (0.51) 4.5 (0.18) 73 (2.87) 84 (3.31) 54 (2.13) Switch, QD Version
84 (3.31) 46 (1.81)
54 (2.13)
82 (3.23) =
46 (1.81) 12 (0.47)
46 (1.81)
12 (0.47)
6 (0.23)
7 16 (0.28) (0.62)
4 (0.16) 11 (0.43) 19 (0.75)
==
4.5 (0.18)
4.5 (0.18)
6 (0.24)
7 16 (0.28) (0.63)
4 (0.16) 11 (0.43) 19 (0.75)
Typical Wiring Diagrams
Cable Brown Safety N.C. Fuse Externally QD
Blue
Safety N.C. Fuse Externally
Application Details
See page 3-54 for operating principles and mounting examples.
46 (1.81)
=
3-49


▲Up To Search▲   

 
Price & Availability of FRS10

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X